Evaluating the diagnostic performance of miLab™ for detection of malaria parasites using nPCR as reference standard

Domain:

healthcare

Record type:

paper
Creator:
EbeTheBenRic
Publisher:
Spr
Host:
Abstract Malaria remains a leading health threat in sub-Saharan Africa, causing over 600,000 deaths annually. Ghana, ranked among the top 15 in malaria burden in Africa, relies heavily on microscopy for diagnosis due to its affordability and established use. However, limitations in sensitivity, turnaround time, and availability of skilled personnel despite ongoing national training efforts stress the need for improved diagnostics. This study evaluated miLab ™ , an AI-assisted automated malaria detection platform, using nested PCR (nPCR) as the reference standard. We conducted a hospital-based cross-sectional study from August 2024 to June 2025 in three malaria-endemic communities in Kumasi, Ashanti region and enrolled 300 suspected malaria patients (168 females, 132 males; aged 1–87 years, median 24). Blood samples were analyzed independently by miLab ™ , two independent mid-level microscopists, and nPCR. Discrepancies between the two microscopists were resolved by a WHO expert microscopist (adjudicated microscopy) to establish a microscopy reference standard. Diagnostic accuracy, correlation and measurement agreement were determined using GraphPad Prism Version 8. Parasite densities estimated by miLab ™ ranged from 0.95 to 5.34 log parasites/µL (median 3.52, IQR 2.93–3.91). For mid-level microscopist 1, densities ranged from 2.02 to 5.43, (median 4.02, IQR: 3.22–4.50), while Mid-level microscopist 2 measured densities between 1.98 and 5.22, (median 3.78, IQR: 3.15–4.23). When compared to nPCR, miLab ™ demonstrated a sensitivity of 94.23%, specificity of 98.98%, and accuracy of 97.33%, while adjudicated microscopy showed a sensitivity of 85.58%, specificity of 97.96%, and accuracy of 93.67%. These findings indicate that miLab ™ has better performance compared to microscopy for detection of malaria parasites. miLab™ could offer a reliable, rapid diagnostic alternative suitable for malaria-endemic, resource-limited settings where timely and accurate diagnosis is critical for effective case management and control.

Visit

doi.org

Languages

Asante

Licenses

https://creativecommons.org/licenses/by/4.0https://creativecommons.org/licenses/by/4.0

Similar

The diagnostic performance of rapid diagnostic tests and microscopy for malaria diagnosis in eastern Sudan using a nested polymerase chain reaction assay as a reference standardDiagnostic accuracy of an automated microscope solution (miLab™) in detecting malaria parasites in symptomatic patients at point-of-care in Sudan: a case–control studyDiagnostic performance of NxTek™ Eliminate Malaria-Pf test for the detection of Plasmodium falciparum in school children with asymptomatic malariaS4.5d Comparing the diagnostic performance of the commonly used eumycetoma diagnostic tests using sequencing of the internally transcribed spacer region as the gold standardEvaluating diagnostic accuracies of Panbio™ test and RT-PCR for the detection of SARS-CoV-2 in Addis Ababa, Ethiopia using Bayesian Latent-Class Models (BLCM)Evaluating the Performance, Quality and Accessibility of Ghanaian Government Portals Using Diagnostic Tools

The diagnostic performance of rapid diagnostic tests and microscopy for malaria diagnosis in eastern Sudan using a nested polymerase chain reaction assay as a reference standard

Abstract Background Accurate diagnosis of malaria infection is essential for successful control a

Diagnostic accuracy of an automated microscope solution (miLab™) in detecting malaria parasites in symptomatic patients at point-of-care in Sudan: a case–control study

Abstract Background Microscopic detection of malaria parasites is labour-intensive, time-consuming,

Diagnostic performance of NxTek™ Eliminate Malaria-Pf test for the detection of Plasmodium falciparum in school children with asymptomatic malaria

Abstract Background One of the major roadblocks to the falcipar

S4.5d Comparing the diagnostic performance of the commonly used eumycetoma diagnostic tests using sequencing of the internally transcribed spacer region as the gold standard

Abstract S4.5 Mycetoma Clinical Trial on fosravuconazole treatm

Evaluating diagnostic accuracies of Panbio™ test and RT-PCR for the detection of SARS-CoV-2 in Addis Ababa, Ethiopia using Bayesian Latent-Class Models (BLCM)

Background Rapid diagnostics are vital for curving the

Evaluating the Performance, Quality and Accessibility of Ghanaian Government Portals Using Diagnostic Tools

International audience In today's world, e-government has become an increasingly impo