Improved Under-Voltage Load Shedding Scheme in Power System Network for South Eastern Nigeria

Domain:

environment and energy
Creator:
ChuObiAmaEze
Publisher:
Zenodo
Host:avatar
This paper presents an Improved Under-Voltage Load Shedding Scheme in Power System for South Eastern Nigeria distribution network. The south eastern Nigeria distribution network was first modeled and its load flow regenerated using Newton Raphson iterative load flow method for all 203 load buses in the network. The aim is to improve the existing network’s bus voltage profile with the use of various under-voltage load shedding schemes for improved power and its effect of the system voltage profile was analyzed and recorded for 100%, 60% and 50% load shedding case studies. Results showed an improvement in the entire network bus voltage level after the load shedding scheme between 10.34 kV to 11.22 kV for 11 kV buses and between 31.02 kV to 33.66 kV for 33 kV buses indicating the nominal voltage level. It showed an increment in the total number of nominal voltage buses of each case study, from 22 buses at 100% load demand to 105 buses when 40% of the load has been shed to finally, 126 buses when 50% of the load has been shed in the 50% load demand scenario A and B. Finally, the number of under-voltage buses decreases to 3 and 7 buses in Scenario A and B respectively when 50% of the total load demand has been shed by Enugu Electric Distribution Company (EEDC).

Visit

doi.orgzenodo.org

Tags

Load Shedding, Under-voltage, Voltage Profile, Overload

Licenses

Creative Commons Attribution 4.0 Internationalhttps://creativecommons.org/licenses/by/4.0/legalcode

Similar

Kgaphola45/Load-Shedding-Energy-Monitoring-SystemNEURAL NETWORK BASED VOLTAGE STABILITY IMPROVEMENT OF THE NIGERIAN 330KV POWER NETWORK USING UNIFIED POWER FLOW CONTROLLER (UPFC) AND HIGH VOLTAGE DIRECT CURRENT (HVDC) DURING CONTINGENCY OF LARGE LOAD GAIN.Development of a Model for Improving Power System Voltage Stability in Nigerian 330kv 48-Bus Network During Loss of Equivalent NetworkLoad Shedding and Crime in South Africa — Replication ArchiveDSS for unit commitment and load sheddingArtificial Neural Network Based Long Term Electrical Peak Load Demand Forecasting in Case of South District Ethiopian Power System

Kgaphola45/Load-Shedding-Energy-Monitoring-System

A powerful SQL Server based database solution designed to track, analyze, and manage load shedding s

NEURAL NETWORK BASED VOLTAGE STABILITY IMPROVEMENT OF THE NIGERIAN 330KV POWER NETWORK USING UNIFIED POWER FLOW CONTROLLER (UPFC) AND HIGH VOLTAGE DIRECT CURRENT (HVDC) DURING CONTINGENCY OF LARGE LOAD GAIN.

This paper presents the neural network-based voltage stability improvement of the Nigeria 330KV Powe

Development of a Model for Improving Power System Voltage Stability in Nigerian 330kv 48-Bus Network During Loss of Equivalent Network

This research work aims at improving the voltage stability of the Nigerian 330KV Power network using

Load Shedding and Crime in South Africa — Replication Archive

Replication archive for "Load Shedding and Crime in South
Africa: Causal Estimates

DSS for unit commitment and load shedding

Contains AIMMS files for setting up and running decision support systems for unit commitmen

Artificial Neural Network Based Long Term Electrical Peak Load Demand Forecasting in Case of South District Ethiopian Power System