In Morocco, the radiation protection of patients undergoing medical imaging examinations using ionizing radiation sources is now governed by specific provisions of Chapter VII of Law n o 142-12 (Loi n o 142-12 – AMSSNuR, 2015). The principle of justification of procedures and the principle of optimization of doses delivered constitute the basis of the legislation governing medical exposure. DRLs are considered as an important optimization tool encouraging healthcare professionals to optimize their practice and assure a better patient safety. In this survey, Local Diagnostic Reference Levels (LDRLs) were established for the eight most frequent examinations in Morocco. Data from 1747 patients were collected from seven regional hospitals. The proposed LDRLs were defined as the 75th percentile of the mean entrance surface dose distribution (ESD) in mGy using the indirect dosimetry method according to the IAEA Report Series No. 457. The LDRLs values reported in this study were for the eight examinations: skull (PA) 2.8 mGy, chest (PA) 0.51 mGy, abdomen (AP) 7.6 mGy, pelvis (AP) 6.45 mGy, lumbar (AP) 7.8 mGy, lumbar (Lat) 10.7 mGy, cervical (AP) 2.2 mGy, and cervical (Lat) 2.4 mGy. The DRLs reported in Morocco were compared with those of international authorities and other countries: IRSN (France), NRPB (UK), Japan, Sudan, and Iran. The present work assesses the local DRLs in Morocco and constitutes a starting point that will provide professionals with a tool to help them optimize the doses delivered to patients. Furthermore, the definition of national DRLs by radiography is an essential step in the process of optimizing medical exposures.

Visit

doi.org

Licenses

https://www.edpsciences.org/en/authors/copyright-and-licensing

Similar

ESTABLISHING LOCAL DIAGNOSTIC REFERENCE LEVELS FOR ROUTINE COMPUTED TOMOGRAPHY EXAMINATIONS IN JIMMA UNIVERSITY MEDICAL CENTER SOUTH WEST ETHIOPIAAn Evaluation of Entrance and Surface Doses for some Common Diagnostic X-ray Examinations in two Nigerian University Teaching HospitalsProposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching HospitalsComputed Tomography local Diagnostic Reference Levels per clinical information in a MozambiqueEvaluation of dose‐area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern NigeriaComputer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithms

ESTABLISHING LOCAL DIAGNOSTIC REFERENCE LEVELS FOR ROUTINE COMPUTED TOMOGRAPHY EXAMINATIONS IN JIMMA UNIVERSITY MEDICAL CENTER SOUTH WEST ETHIOPIA

Abstract The main purpose of this study was to determine local diagnostic reference

An Evaluation of Entrance and Surface Doses for some Common Diagnostic X-ray Examinations in two Nigerian University Teaching Hospitals

Background: The aims of this study were to estimate Entrance Surface Dose (ESDs) to patients undergo

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have

Computed Tomography local Diagnostic Reference Levels per clinical information in a Mozambique

Purpose or learning objective Methods or background Results or findings Conclusion References Person

Evaluation of dose‐area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria

In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic

Computer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithms

Use of computer-aided detection (CAD) software is recommended to improve tuberculosis screening and