Logo Lanfrica
  • Home
  • Atlas
  • Insights
  • Docs
  • Sign in

© 2026 Lanfrica. All rights reserved. All copyrights of the resources shown on the Lanfrica website belong to the original copyright holders, unless explicitly stated otherwise.

Optimizing Computer-Aided Detection for Tuberculosis (CAD4TB) Thresholds for Community TB Screening in Nigeria: Recalibrating Threshold with Local Data

Domain:

healthcare

Record type:

papersoftware
Creator:
BetOjuCleOko
Editor:
KnoDepDepDep
Publisher:
CCSD
Host:avatar
International audience Background: Computer-aided detection (CAD) is a promising tool for tuberculosis (TB) screening, but its performance, particularly the optimal abnormality score thresholds, is highly context-specific. This study aimed to optimise the use of computer-aided detection (CAD4TB) software in tuberculosis (TB) screening by customising its threshold settings based on individual patient characteristics and reported symptoms.Method: The study was a retrospective observational study utilizing secondary data from community-based TB screening using portable digital X-ray (PDX) with CAD4TB AI. A total of 18,529 adults were screened across various settings, with 16,047 participants having complete results on both CAD4TB and molecular tests (GeneXpert). Most participants were from the general population (35.0%), slums (25.3%), and hard-to-reach areas (16.5%). The mean CAD4TB score was 43.13 (range: 0–99.3). CAD4TB AI findings were validated against molecular results to determine diagnostic accuracy, sensitivity, specificity; PPV, and NPV were calculated, and ROC curves were generated to assess AI score thresholds and case detection yield by age and setting.Findings: The mean age was 43.5 ± 18.4 years; 62.6% were males. The study found a high TB prevalence of 10.9%. The performance of CAD exhibited significant variation among individuals with a prior history of tuberculosis. The optimal threshold for this subgroup was a score of 48 (sensitivity 91.0%, specificity 41.9%, AUC 0.76), compared to a score of 36 for those without prior TB (sensitivity 90.6%, specificity 39.0%, AUC 0.81). This confirms that CAD accuracy is reduced among people previously treated for TB, likely due to post-TB radiological sequelae. While no single threshold met the WHO Target Product Profile (≥90% sensitivity and ≥70% specificity) for the entire population, the study demonstrated CAD's good overall accuracy (AUC >0.80) and its value as a high-sensitivity screening tool.Conclusion: CAD is an effective tool for community-based TB screening in Nigeria. However, its implementation requires locally validated, context-specific thresholds rather than universal cut-offs. Programmes must adopt different thresholds for key subgroups, such as those with a previous history of TB, to balance case detection with cost-effectiveness. Continuous re-evaluation of thresholds with each software update is essential to maintain optimal performance and impact.

Visit

hal.science

Tags

[INFO.INFO-IM]Computer Science [cs]/Medical Imaging

Similar

Evaluating InferVision’s Computer-Aided Detection (CAD) algorithm for Tuberculosis (TB) screening, Lusaka, ZambiaComputer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithmsThe use of computer-aided detection for tuberculosis (TB) diagnosis in the Bono East, GhanaDiagnostic accuracy of Computer-Aided Detection for Tuberculosis® and Stool Xpert for detecting TB in prospectively recruited West African childrenPerformance of Human and Computer-aided Evaluation of Digital Chest Radiography for Community-based Screening of Asymptomatic TuberculosisCOLODETECT 1: comparative evaluation of endocuff with computer-aided detection versus computer-aided detection alone versus standard colonoscopy for enhancing adenoma detection rates during screening colonoscopy—a pilot study

Evaluating InferVision’s Computer-Aided Detection (CAD) algorithm for Tuberculosis (TB) screening, Lusaka, Zambia

The objective of this study was to evaluate the diagnostic performance of InferRead DR Chest for tub

Computer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithms

Use of computer-aided detection (CAD) software is recommended to improve tuberculosis screening and

The use of computer-aided detection for tuberculosis (TB) diagnosis in the Bono East, Ghana

Diagnostic accuracy of Computer-Aided Detection for Tuberculosis® and Stool Xpert for detecting TB in prospectively recruited West African children

Introduction • Tuberculosis (TB) diagnosis in children is challenging due to the difficulty in obta

Performance of Human and Computer-aided Evaluation of Digital Chest Radiography for Community-based Screening of Asymptomatic Tuberculosis

Abstract Background The World Health Organ

COLODETECT 1: comparative evaluation of endocuff with computer-aided detection versus computer-aided detection alone versus standard colonoscopy for enhancing adenoma detection rates during screening colonoscopy—a pilot study

International audience Background: Independent use of artificial intelligence with co