Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

BCID2 panel system usability score (N=5).

Domaine:

healthcare

Type de record:

paper
Créateur:
TinIoaGweMut
Hôte:avatar

Background

Sepsis is a major cause of mortality in low-resource settings. Effective microbiological culture services are a bottleneck in diagnosis and surveillance.

Aim

We aimed to evaluate the performance of the BIOFIRE FILMARRAY Blood Culture Identification 2 (BCID2, bioMérieux) assay in a low-resource setting laboratory in comparison to standard practice.

Methods

This five month prospective validation study included all positive blood cultures collected at Sally Mugabe Central Hospital, Harare, Zimbabwe. BCID2 testing was done in parallel to standard phenotypic procedures and resistance testing. Reference identification was performed using mass spectrometry or whole genome sequencing. Only samples with available reference standard results were included in the analysis. Data captured on paper-based forms was entered into electronic case report forms (ODK Collect). Specificity and sensitivity for BCID2 were calculated in comparison to the reference standards, with performance measures calculated using the Wilson score. Biomedical scientists using BCID2 completed a system usability survey (SUS).

Results

Positive results were recorded in 780/2,023 (38.5%) blood cultures, within which 377 (48.3%) had reference results and so were included in analysis. Neonatal samples were most frequent (182, 48.3%), then paediatric (150, 39.8%), then adults (18, 4.8%) and unknown (27, 7.2%). Specificity exceeded 95% throughout. Sensitivity ranged from 50% (A. calcoaceticus-baumanii complex, Proteus spp.) to 100% (S. pneumoniae, Salmonella spp). Using BCID2, CTX-M was detected in 111/175 (74.5%) Enterobacterales, from which 5/111 also had NDM and VIM detected. NDM-5 was detected in 2/5 NDM samples using sequencing. In total 3/23 S. aureus isolates were methicillin resistant, from which one was confirmed using phenotypic antimicrobial susceptibility testing. Usability was good (SUS score = 79.5).

Conclusion

Rapid molecular tests have potential to improve turn-around time and quality of sepsis diagnostics. However, specific work-flows are critical to supplement molecular tests with minimal phenotypic tests for optimal clinical decision-making.

Visit

figshare.com

Tags

MedicineCell BiologyMolecular BiologyBiotechnologyDevelopmental BiologyCancerScience PolicyInfectious DiseasesVirologyChemical Sciences not elsewhere classified+45

Licenses

CC BY 4.0