Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Computer-Aided Detection (CAD) Software Versus Radiologists from Multiple Countries: A Comparison of Tuberculosis Detection from Chest X-Rays

Domaine:

healthcare

Type de record:

paper
Créateur:
ZhiMarSizFar
Éditeur:
Spr
Hôte:
Abstract Nearly a third of TB cases go undetected annually. WHO recommends computer-aided detection (CAD) to enhance TB screening, with studies showing comparable performance to local radiologists. Using 774 chest X-rays from the South African National TB Prevalence Survey, we compared 12 CAD software with 11 radiologists from Nigeria, India, the UK, and the US, against a composite microbiological reference standard. Sensitivity, specificity and Cohen’s kappa were calculated and compared. Receiver-operating characteristic curves were developed for CAD and Euclidean distance assessed radiologists’ alignment with the best-performing software. Binomial regression tested the impact of radiologists’ characteristics on accuracy. Radiologist performance varied. On the restricted read, British radiologists had the highest sensitivity (78.7% [73.2–83.5%]) and Indian radiologists the lowest (67.1% [61.0-72.8%]). Specificity ranged from 75.8% (71.8–79.4%, Nigeria) to 84.3% (80.9–87.3%, the US). The top CAD outperformed all except Indian radiologists when matching specificity. CAD with Conformité Européenne (CE) generally matched or surpassed radiologists. British radiologists’ sensitivity was closest to the top CAD, while American radiologists were closest in specificity and overall. Experience, TB reads, and country had no significant impact on accuracy. CAD performed well against radiologists globally, underscoring its potential to enhance access to care.

Visit

doi.org

Tasks

computer visionimage classification

Licenses

https://creativecommons.org/licenses/by/4.0/

Similaires

On AI-Assisted Pneumoconiosis Detection from Chest X-raysCOMPUTER-AIDED TUBERCULOSIS DETECTION IN CHEST RADIOGRAPHS: A SURVEYHybrid DenseNet121-Transformer Architecture for Tuberculosis Detection from Merged Multi-Source Chest X-RaysComputer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithmsDeep Learning in Medical Imaging: Using Densenet121 for Automated Tuberculosis Detection from Chest X-RaysEvaluating InferVision’s Computer-Aided Detection (CAD) algorithm for Tuberculosis (TB) screening, Lusaka, Zambia

On AI-Assisted Pneumoconiosis Detection from Chest X-rays

According to theWorld Health Organization, Pneumoconiosis affects millions of workers globally, wi

COMPUTER-AIDED TUBERCULOSIS DETECTION IN CHEST RADIOGRAPHS: A SURVEY

Tuberculosis (TB) is very dangerous and rapidly spread disease in the world. In the investi

Hybrid DenseNet121-Transformer Architecture for Tuberculosis Detection from Merged Multi-Source Chest X-Rays

Tuberculosis (TB) causes over 1.5 million deaths annually, disproportionately affecting developing n

Computer-aided detection thresholds for digital chest x-ray interpretation in tuberculosis diagnostic algorithms

Use of computer-aided detection (CAD) software is recommended to improve tuberculosis screening and

Deep Learning in Medical Imaging: Using Densenet121 for Automated Tuberculosis Detection from Chest X-Rays

ABSTRACT:Millions of reported cases and associated deaths highlight the annual global threa

Evaluating InferVision’s Computer-Aided Detection (CAD) algorithm for Tuberculosis (TB) screening, Lusaka, Zambia

The objective of this study was to evaluate the diagnostic performance of InferRead DR Chest for tub