Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Concordance Study on Population Database Samples Using the PowerPlex™ 16 Kit and AmpFℓSTR® Profiler Plus™ Kit and AmpFℓSTR® COfiler™ Kit

Domaine:

healthcare
Créateur:
B BCJ
Éditeur:
AST
Hôte:
Abstract Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex™ 16 and the Profiler Plus™ COfiler™ kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex™ 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex™ 16, Profiler Plus™, and COfiler™ kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.

Visit

doi.org

Similaires

Allele frequencies for 15 STR loci in Ovambo population using AmpFlSTR® Identifiler KitDiagnostic accuracy of VIKIA® Rota-Adeno and Premier™ Rotaclone® tests for the detection of rotavirus in NigerPluriversal AI™wh0isalfred/KitBio-efficacy and wash-fastness of a lambda-cyhalothrin long-lasting insecticide treatment kit (ICON® Maxx) against mosquitoes on various polymer materialsKnowledge, attitudes and practices (KAP) to assess the impact of school children's awareness of malaria using the MOSKI KIT® tool: study case of some Dakar schools in Senegal

Allele frequencies for 15 STR loci in Ovambo population using AmpFlSTR® Identifiler Kit

Diagnostic accuracy of VIKIA® Rota-Adeno and Premier™ Rotaclone® tests for the detection of rotavirus in Niger

International audience OBJECTIVE:We conducted a parallel evaluation of the diagnostic

Pluriversal AI™

This document constitutes the founding Pioneer Declaration of Pluriversal AI™ —

wh0isalfred/Kit

A kids' tech-education platform in Port Harcourt, Nigeria. Ages 10–15 # KIT Project Documentation —

Bio-efficacy and wash-fastness of a lambda-cyhalothrin long-lasting insecticide treatment kit (ICON® Maxx) against mosquitoes on various polymer materials

Abstract Background Long-lasting efficacy of insecticide-treate

Knowledge, attitudes and practices (KAP) to assess the impact of school children's awareness of malaria using the MOSKI KIT® tool: study case of some Dakar schools in Senegal

Abstract Background MOSKI KIT® is a fun tool designed to interest children for preventio