Correcting for measurement error in assessing gestational age in a low-resource setting: a regression calibration approach

Domaine:

healthcare
Créateur:
GeoJenNanBry
Éditeur:
Fro
Hôte:
Introduction Measurement error in gestational age (GA) may bias the association of GA with a health outcome. Ultrasound-based GA is considered the gold standard and is not readily available in low-resource settings. We corrected for measurement error in GA based on fundal height (FH) and date of last menstrual period (LMP) using ultrasound from the sub-cohort and adjusted for the bias in associating GA with neonatal mortality and low birth weight (< 2,500 grams, LBW). Methods We used data collected from 01/2015 to 09/2019 from pregnant women enrolled at two public hospitals in Siaya county, Kenya ( N  = 2,750). We used regression calibration to correct for measurement error in FH- and LMP-based GA accounting for maternal and child characteristics. We applied logistic regression to associate GA with neonatal mortality and low birth weight, with and without calibrating FH- and LMP-based GA. Results Calibration improved the precision of LMP (correlation coefficient, ρ from 0.48 to 0.57) and FH-based GA ( ρ from 0.82 to 0.83). Calibrating FH/LMP-based GA eliminated the bias in the mean GA estimates. The log odds ratio that quantifies the association of GA with neonatal mortality increased by 29% (from −0.159 to −0.205) by calibrating FH-based GA and by more than twofold (from −0.158 to −0.471) by calibrating LMP-based GA. Conclusion Calibrating FH/LMP-based GA improved the accuracy and precision of GA estimates and strengthened the association of GA with neonatal mortality/LBW. When assessing GA, neonatal public health and clinical interventions may benefit from calibration modeling in settings where ultrasound may not be fully available.

Visit

doi.org

Licenses

https://creativecommons.org/licenses/by/4.0/

Similaires

Acceptability and Feasibility of a Low-Cost Device for Gestational Age Assessment in a Low-Resource Setting: Qualitative StudyCalibration of the Epilepsy Questionnaire for Use in a Low-Resource SettingThe acceptability and feasibility of a low-cost device for gestational age assessment in a low resources setting: A qualitative assessment (Preprint)Predicting stillbirth in a low resource settingNeonatal Mortality is Modulated by Gestational Age, Birthweight and Fetal Heart Rate Abnormalities in the Low Resource Setting in Tanzania – a Five Year Review 2015-2019Gestational age estimation in resource poor settings

Acceptability and Feasibility of a Low-Cost Device for Gestational Age Assessment in a Low-Resource Setting: Qualitative Study

Background Ultrasound for gestational age (GA) assessment is not routinely available i

Calibration of the Epilepsy Questionnaire for Use in a Low-Resource Setting

Background . Burden of epilepsy in sub-Saharan Africa is huge in the midst of shortage of human reso

The acceptability and feasibility of a low-cost device for gestational age assessment in a low resources setting: A qualitative assessment (Preprint)

BACKGROUND Ultrasound for gestational age (GA) assessment is not routinely

Predicting stillbirth in a low resource setting

Abstract Background Stillbirth is a major contributor to perinatal mortality and it is particularly

Neonatal Mortality is Modulated by Gestational Age, Birthweight and Fetal Heart Rate Abnormalities in the Low Resource Setting in Tanzania – a Five Year Review 2015-2019

Abstract Background Neonatal mortality (NM) remains a significant problem in low resource

Gestational age estimation in resource poor settings

Background and objectives: The incidence of preterm birth (PTB), and the extent to