Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Establishment of haemoglobin A2 reference intervals in Pretoria, South Africa: A retrospective secondary data analysis

Domaine:

healthcare
Créateur:
CaiTshJoh
Éditeur:
AOS
Hôte:
Background: Haemoglobinopathies are one of the most common inherited diseases worldwide. Quantification of haemoglobin A2 is necessary for the diagnosis of the beta thalassaemia trait. In this context, it is important to have a reliable reference interval for haemoglobin A2 and a local reference range for South Africa has not been established.Objective: This study aimed to establish reference intervals for haemoglobin A2 using stored patient laboratory data.Methods: This descriptive study used retrospective data to evaluate haemoglobin A2 levels determined using high-performance liquid chromatography at the National Health Laboratory Service haematology laboratory in Pretoria, South Africa. All tests performed from 01 October 2012 to 31 December 2020 were screened for inclusion; of these, 144 patients’ data met the selection criteria. The reference interval was calculated using descriptive statistics (mean and standard deviation) with a 95% confidence interval.Results: Analysed data from enrolled patients showed a normal distribution. The mean age of the patients was 40 years (range: 3–84 years). The reference interval for haemoglobin A2 calculated from this data was 2.3% – 3.6%. The minimum haemoglobin A2 was 2.3% and the maximum was 3.9% with a mean of 2.95% and a standard deviation of 0.357%.Conclusion: A normal reference interval has been established for the population served by the laboratory that will assist with accurate diagnosis of the beta thalassaemia trait. This reference interval may also be useful to other laboratories that employ the same technology, especially smaller laboratories where obtaining a sufficiently large number of normal controls may be challenging.

Visit

doi.org

Licenses

https://creativecommons.org/licenses/by/4.0

Similaires

Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adultsEstablishment of the hematology reference intervals in a healthy population of adults in the Northwest of Morocco (Tangier-Tetouan region)Tshwane, a San Name for Pretoria, South AfricaRetrospective analysis of CD4 count trends in South AfricaRetrospective Study of the Burden of Avian influenza in Kano State, Nigeria: A secondary Data Analysis 2015-2017The profile of pleural effusions in oncological patients referred to the cardiothoracic surgery department in a tertiary hospital in Pretoria, South Africa: A retrospective study

Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults

Introduction The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simul

Establishment of the hematology reference intervals in a healthy population of adults in the Northwest of Morocco (Tangier-Tetouan region)

Tshwane, a San Name for Pretoria, South Africa

Abstract Tshwane is the Tswana name for the Apies River. This name has been used by Tswana speakers

Retrospective analysis of CD4 count trends in South Africa

Background: South Africa has the largest HIV epidemic globally. Despite the scale-up of antiretrovir

Retrospective Study of the Burden of Avian influenza in Kano State, Nigeria: A secondary Data Analysis 2015-2017

Over 1.2 million poultry birds were infected with highly pathogenic avian influenza (HPAI) (H5N1) in

The profile of pleural effusions in oncological patients referred to the cardiothoracic surgery department in a tertiary hospital in Pretoria, South Africa: A retrospective study

Background. The presence of a pleural effusion in any oncological patient (patient with known underl