Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Frequency stabilization of a sophisticated multi-area interconnected hybrid power system considering non-inertia sources Author links open overlay panel

Domaine:

environment and energy

Type de record:

software
Créateur:
GawMagEbrPet
Éditeur:
Int
Hôte:avatar
This study introduces a novel interconnected power system model, which combines four real areas, integrating conventional power plants with renewable energy sources (RESs). This comprehensive system model aims to address the load frequency control (LFC) challenges that such systems face. Where the integration of RESs into power systems poses significant challenges, particularly in maintaining frequency stability. The LFC approach utilizes a proportional-integral-derivative (PID) controller, meticulously optimized through the Runge-Kutta (RUN) optimizer based on its mathematical principles. Dealing with the uncertainties of RESs and system nonlinearities poses a significant challenge for this controller. The efficacy of the proposed PID controller based on the RUN algorithm is examined by analyzing the frequency stability of the Egyptian power system (EPS), which stays interconnected with neighboring grids in Jordan, Libya, and Sudan. This study accounts for various loading scenarios and system nonlinearities to validate the algorithm’s effectiveness. Furthermore, the superior performance of the RUN optimizer is verified by contrasting its results with other widely recognized optimization techniques, such as the Ant Lion optimizer (ALO) and Chernobyl disaster optimizer (CDO). Additionally, the PID controller based on the RUN optimizer is also evaluated against literature that employed a moth swarm algorithm (MSA) to design the PID controller-based LFC in the EPS. Simulation results in the MATLAB environment demonstrate the effectiveness and robustness of the proposed PID controller based on the RUN algorithm. The RUN-based PID controller outperforms other PID controllers optimized using algorithms from the literature (e.g., ALO, CDO, and MSA), achieving superior performance across various contingencies, including load variations, RES uncertainties, and system nonlinearities. The results highlight the effectiveness of the proposed controller compared to those in the literature, improving the maximum overshoot by approximately 20% and reducing the minimum undershoot by about 30%. As a result, the system reaches steady-state conditions roughly 15 s faster. Finally, to leverage the precision of physical simulation and the flexibility of numerical simulation, the proposed PID controller, based on the RUN algorithm, is validated and implemented in a real-time environment using the OPA-RT platform.

Visit

doi.org

Tags

Load frequency control, Real interconnected power system,PID controller, Renewable energy sources (RESs), Runge Kutta (RUN) optimizer

Licenses

info:eu-repo/semantics/openAccessCreative Commons Attribution 4.0 Internationalhttps://creativecommons.org/licenses/by/4.0/legalcode

Similaires

Hybrid ANFIS-Based Fuzzy-PID Controller Design for Multi-Area Load Frequency Control in the Northwest Ethiopian Power GridAnalysis of frequency control and grid storage effectiveness for a west African interconnected transmission systemFEASIBILITY STUDY OF SOLAR-WIND HYBRID POWER SYSTEM FOR MAIDUGURI AREA OF NIGERIAKernel estimation modelling and optimization of hybrid power system for a typical South African rural areaConsidering Power System Planning in Fragile and Conflict StatesFeasibility Analysis and Development of Stand-Alone Hybrid Power Generation System for Remote Areas: A Case Study of Ethiopian Rural Area

Hybrid ANFIS-Based Fuzzy-PID Controller Design for Multi-Area Load Frequency Control in the Northwest Ethiopian Power Grid

Abstract The demand for electricity is rising daily, causing a mismatch between ge

Analysis of frequency control and grid storage effectiveness for a west African interconnected transmission system

The West Africa Power Pool (WAPP) Interconnected Transmission System (WAPPITS) has faced challenges

FEASIBILITY STUDY OF SOLAR-WIND HYBRID POWER SYSTEM FOR MAIDUGURI AREA OF NIGERIA

Kernel estimation modelling and optimization of hybrid power system for a typical South African rural area

To increase the accessibility of electricity even to those rural sparsely scattered isolated rural r

Considering Power System Planning in Fragile and Conflict States

Abstract Traditional methods of energy planning are likely to provide results that may be inappropri

Feasibility Analysis and Development of Stand-Alone Hybrid Power Generation System for Remote Areas: A Case Study of Ethiopian Rural Area

This paper proposed a standalone solar/wind/micro-hydro hybrid power generation system to electrify