Generalization of AI-Based Gestational Age Assessment Using Blind Sweep Ultrasonography

Domaine:

healthcare

Type de record:

modelpaper
Créateur:
AngChaJusAnn
Éditeur:
Ame
Hôte:
Importance Artificial intelligence (AI) systems have been developed to estimate gestational age (GA) based on blind sweep ultrasonography scans performed by novice operators. However, their generalizability to new clinical contexts outside original training settings requires evaluation. Objective To investigate the ability of a previously trained AI system to interpret blind sweep ultrasonography scans for GA estimation to generalize to new clinical environments. Design, Setting, and Participants This prospective diagnostic study compares AI model performance against the clinical standard for GA determination. The model was primarily accessed following lightweight adaptation using data from 1 setting. From a broader cohort of 2043 participants (1008 in Chicago and 1035 in Nairobi), datasets included an adaptation set of 120 Chicago participants (split evenly for training and validation) and a primary evaluation set of 385 participants (192 in Chicago and 193 in Nairobi) with GAs of 16 to 36 weeks. The study took place in 2 urban medical institutions, 1 in Chicago, Illinois (March 7, 2022, to May 28, 2024) and 1 in Nairobi, Kenya (January 8 to September 2, 2024). Data were analyzed April 21 to June 4, 2025. Intervention A mobile application containing the AI system for GA estimation, with data collected via a protocolized blind sweep procedure by novice operators. Main Outcomes and Measures The primary outcome was the mean absolute error (MAE) of the fine-tuned AI’s GA estimation compared with the clinical standard (expert sonographer estimate), using a 1-day noninferiority margin. Results The primary evaluation set included 385 participants (mean [SD] maternal age, 31.3 [5.6] years). The adapted model achieved an MAE of 4.1 days (95% CI, 3.5-4.7) in Chicago and 4.3 days (95% CI, 3.8-4.8 days) in Nairobi. Overall, the AI model demonstrated noninferiority to clinical standard estimates (MAE, 4.2 days [95% CI, 3.8-4.6 days] vs 4.5 days [95% CI, 4.1-4.9 days]; P  < .001). Conclusions and Relevance These findings suggest that the AI model for GA estimation, using blind sweep data collected by novice operators, demonstrated generalization to new clinical settings and a different ultrasonography probe. This study highlighted the potential of AI-based ultrasonography assessment to expand access to care through scalable cross-setting deployment, particularly in low-resource settings.

Visit

doi.org

Similaires

Diagnostic Accuracy of an Integrated AI Tool to Estimate Gestational Age From Blind Ultrasound SweepsDeep learning to estimate gestational age from blind ultrasound sweeps of the gravid abdomenReal world external validation of metabolic gestational age assessment in KenyaAgreement between algorithmic gestational age estimations compared to ultrasound-assigned gestational age.Machine Learning Guided Postnatal Gestational Age Assessment Using Newborn Screening Metabolomic Data in South Asia and Sub-Saharan AfricaA mobile-optimized artificial intelligence system for gestational age and fetal malpresentation assessment

Diagnostic Accuracy of an Integrated AI Tool to Estimate Gestational Age From Blind Ultrasound Sweeps

Importance Accurate assessment of gestational age (GA) is essential to good pregnancy care but ofte

Deep learning to estimate gestational age from blind ultrasound sweeps of the gravid abdomen

ABSTRACT Background Ultrasound is indispen

Real world external validation of metabolic gestational age assessment in Kenya

Abstract Using data from Ontario Canada, we previously developed machine learning-

Agreement between algorithmic gestational age estimations compared to ultrasound-assigned gestational age.

(A) Legend, and overall MAE (95% CI) for heel prick sample and cord blood samples from Zambia and

Machine Learning Guided Postnatal Gestational Age Assessment Using Newborn Screening Metabolomic Data in South Asia and Sub-Saharan Africa

Abstract Background: Babies born early and/or small for gestational age in Low- and Midd

A mobile-optimized artificial intelligence system for gestational age and fetal malpresentation assessment

Abstract Background Fetal ultrasound is an important component