Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Greenhouse gas network design using backward Lagrangian particle dispersion modelling – Part 2: Sensitivity analyses and South African test case

Domaine:

climateenvironment and energy

Type de record:

paper
Créateur:
A. T. P. R.
Éditeur:
Cop
Hôte:
Abstract. This is the second part of a two-part paper considering network design based on a Lagrangian stochastic particle dispersion model (LPDM), aimed at reducing the uncertainty of the flux estimates achievable for the region of interest by the continuous observation of atmospheric CO2 concentrations at fixed monitoring stations. The LPDM model, which can be used to derive the sensitivity matrix used in an inversion, was run for each potential site for the months of July (representative of the Southern Hemisphere Winter) and January (Summer). The magnitude of the boundary contributions to each potential observation site was tested to determine its inclusion in the network design, but found to be minimal. Through the use of the Bayesian inverse modelling technique, the sensitivity matrix, together with the prior estimates for the covariance matrices of the observations and surface fluxes were used to calculate the posterior covariance matrix of the estimated fluxes, used for the calculation of the cost function of the optimisation procedure. The optimisation procedure was carried out for South Africa under a standard set of conditions, similar to those applied to the Australian test case in Part 1, for both months and for the combined two months. The conditions were subtly changed, one at a time, and the optimisation routine re-run under each set of modified conditions, and compared to the original optimal network design. The results showed that changing the height of the surface grid cells, including an uncertainty estimate for the oceans, or increasing the night time observational uncertainty did not result in any major changes in the positioning of the stations relative to the basic design, but changing the covariance matrix or increasing the spatial resolution did. The genetic algorithm was able to find a slightly better solution than the incremental optimisation procedure, but did not drastically alter the solution compared to the standard case. Including correlation appeared to increase the spread in the layout of the stations. Increasing the surface resolution tended to clump the stations around areas of high activity. In conclusion, the specification used in an optimal network design should be chosen to best match the conditions under which an inversion would be run for the region of interest. Increasing the spatial resolution beyond that which the given network size could reasonably resolve may lead to a network which would ignore small areas of high activity and reduce the capacity of the network to resolve fluxes for subregions in the domain of interest. Overall the results suggest that a good improvement in knowledge of South African fluxes is available from a feasible atmospheric network and that the general features of this network are robust to many reasonable choices in a network design study.

Visit

doi.org

Licenses

https://creativecommons.org/licenses/by/3.0/

Similaires

Greenhouse gas observation network design for AfricaModelling the greenhouse gas impact of volatile anaesthetic agents in South AfricaModelling and Simulation of Natural Gas Condensate Production Using Artificial Neural NetworkTowards long-term greenhouse gas observations in Africa - a design studyOpportunities for an African greenhouse gas observation systemSelected sensitivity analyses.

Greenhouse gas observation network design for Africa

Optimal design of a tall tower observation network for greenhouse gases (CO2, CH4 and N2O) over Afri

Modelling the greenhouse gas impact of volatile anaesthetic agents in South Africa

Desflurane has been removed from practice across the National Health Service (NHS) hospitals in the

Modelling and Simulation of Natural Gas Condensate Production Using Artificial Neural Network

Abstract Natural gas condensates are hydrocarbon liquid streams separated from natu

Towards long-term greenhouse gas observations in Africa - a design study

Opportunities for an African greenhouse gas observation system

Abstract Global population projections foresee the biggest increase to occur in Africa with most of

Selected sensitivity analyses.

Sensitivity of the model for the prevalence of tuberculosis, for the prevalence of multidrug-resi