Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Reference intervals of common clinical biochemistry analytes in young Nigerian adults

Domaine:

healthcare

Type de record:

dataset
Créateur:
OjoNatNurTah
Éditeur:
Pub
Hôte:
Background Reference intervals are assessment tools for interpretation of clinical test results. These intervals describe the dispersion of test parameter values of apparently healthy persons in defined populations as health status indicators. Using reference intervals obtained and validated in populations outside the geographical region of derivation for medical decision-making may impact negatively on clinical interpretation and patient management. Many countries have established their reference values, current studies on these data for Nigeria are however scarce. Determination of clinical biochemistry reference intervals for young Nigerian adults which is of particular importance in routine clinical management and conduct of clinical trials in response to existing and emerging diseases will add significantly to the existing body of knowledge. Objective The objective was to establish reference intervals for 24biochemistry analytes among Nigerians aged 18 to 26 years. Methods This was a cross-sectional study among 7,797 consenting male and female military applicants aged 18 to 26 years from 37 States of Nigeria. It was a total study among volunteers for military service. Blood samples were collected and subjected to serological testing for HIV-1 and 2, hepatitis-B, malaria, pregnancy and haematuria to restrict our study population to apparently healthy participants. Biochemical assays were performed on 6,169 participant samples that met the inclusion criteria. Generated data was entered into MS Excel ® and exported into SPSS ® software version 16 for analysis. Statistical tools used were frequencies, median, mid 95 th percentile range with 2.5 th and 97.5 th percentiles as limits. Reference intervals were estimated using nonparametric methods. No intergender statistical comparison was made. Results Complete records were obtained for 6,169 eligible participants. Median values and associated reference intervals were similar in both genders. Conclusion The findings from this study will help in clinical decision-making and play a significant role in supporting the current global rapid expansion of clinical trials in response to the urgent need for preventive and therapeutic solutions to existing and emerging diseases.

Visit

doi.org

Licenses

http://creativecommons.org/licenses/by/4.0/

Similaires

CLSI-derived hematology and biochemistry reference intervals for healthy adults in eastern and southern Africa.Clinical Chemistry & BiochemistryNormative Clinical Reference for Intima-media Thickness of Carotid Arteries Among Nigerian AdultsMOESM1 of Hematological reference intervals determination in adults at Gondar university hospital, Northwest EthiopiaEstablishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adultsCorrection: Determination of reference intervals for common chemistry and immunoassay tests for Kenyan adults based on an internationally harmonized protocol and up-to-date statistical methods

CLSI-derived hematology and biochemistry reference intervals for healthy adults in eastern and southern Africa.

BACKGROUND: Clinical laboratory reference intervals have not been established in many African countr

Clinical Chemistry & Biochemistry

⚠️ Synthetic dataset — Parameterized from published SSA literature, not real observations. Not suita

Normative Clinical Reference for Intima-media Thickness of Carotid Arteries Among Nigerian Adults

Background: The intima-media thickness (IMT) of the carotid arteries is said to be pre

MOESM1 of Hematological reference intervals determination in adults at Gondar university hospital, Northwest Ethiopia

Additional file 1. Questionnaire for data collection of a study on Hematological reference intervals

Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults

Introduction The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simul

Correction: Determination of reference intervals for common chemistry and immunoassay tests for Kenyan adults based on an internationally harmonized protocol and up-to-date statistical methods