This deposit provides the supporting datasets and engineering design calculations for the manuscript “As-built CAD and ANSYS structural-thermal validation of a locally fabricated anaerobic co-digester for institutional organic waste in Uganda”, prepared for submission to F1000Research.
The final auditable workbook (UTC_Bushenyi_Anaerobic_Digester_Auditable_Dataset.xlsx) contains the data dictionary, waste inventory, laboratory measurements and calculations, C/N-constrained mixture optimisation, 29-day commissioning observations, gas-screening results, geometry and material inputs, ANSYS results, and quality-control notes.
DESIGN DIGESTER.xlsx is retained as a legacy preliminary design-calculation workbook. Its values are earlier planning assumptions and may differ from the final auditable dataset and manuscript; users should cite and use the auditable workbook for final reported results.
The associated study reports theoretical biogas potential, structural simulation, and commissioning observations. The theoretical yields are not experimentally measured methane-production data.