Toxicological impact of gasoline generator emissions using rat models

Domaine:

healthcareenvironment and energy
Créateur:
DepOluGodDav
Éditeur:
ASE
Hôte:
Nigeria has been identified as one of the largest active users of gasoline generators globally. Due to the widespread incessant use of gasoline generators, the present study assessed the exposure to gasoline generator emission (GGE) and some toxicity endpoints. This study employed a laboratory-based experimental design. An emission chamber was designed using clear thermoplastic to house the rats during exposure to 0.5KVA GGEs. Three experimental groups, each with eight rats respectively, were subjected to 5, 10, 15 minutes of of daily GGE exposure for fourteen days for fourteen days, while the fourth was a control group. Selected air quality parameters were measured using the appropriate samplers. Assays like liver function tests, antioxidant enzyme activity, and micronucleus frequency were conducted after the experiment. Micronucleus frequency significantly increased with time of GGE exposure (p=0.000), while the liver tissue antioxidant activity of the test groups was significantly higher than that of the control group (p<0.05). Moreover, histopathological examinations revealed lesions like sinusoidal congestion and vacuolar degeneration of the hepatocytes in liver tissues of the exposed rats. However, the liver function test showed a non-significant association with their level of GGE exposure. The result of this study suggested that exposure to GGEs at a non-lethal concentration in a sub-acute or chronic manner has deleterious effects on mammalian biochemical systems. Therefore, the use of exhaust filters and improvement in the ventilating systems of houses are encouraged to reduce exposure rates in developing countries like Nigeria, where GGEs are widespread due to erratic electricity supply.

Visit

doi.org

Similaires

Exposure to gasoline power generator exhaust fume negatively affected hematological, liver and kidney function parameters in female albino rats (766.7)Forecasting of CO2 Emissions in Algeria Using Discrete Wavelet Transform –Based Autoregressive Integrated Moving Average ModelsDeterminants of Gasoline and Diesel Demand in EthiopiaAwareness of Toxicological Impact and Risk of using Talcum Powder as a factor for Ovarian Cancer among Women in three Metropolitan Cities of Southwestern States of NigeriaEstimating the impact of interventions on viral epidemics using epidemiological and evolutionary modelsDesign and Performance Evaluation of a Battery-Assisted Fuel-Less Generator Using a Permanent Magnet Synchronous Generator with Automated Feedback Control

Exposure to gasoline power generator exhaust fume negatively affected hematological, liver and kidney function parameters in female albino rats (766.7)

The lack of constant electricity power supply to meet utility usage in developing countries like Nig

Forecasting of CO2 Emissions in Algeria Using Discrete Wavelet Transform –Based Autoregressive Integrated Moving Average Models

Abstract The increasing impact of climate change and rising temperatures has made the redu

Determinants of Gasoline and Diesel Demand in Ethiopia

In this paper attempts are made to identify determinants of gasoline and diesel demand in Ethiopia.

Awareness of Toxicological Impact and Risk of using Talcum Powder as a factor for Ovarian Cancer among Women in three Metropolitan Cities of Southwestern States of Nigeria

Abstract ABSTRACT: This study evaluated the public awareness level on the toxicological

Estimating the impact of interventions on viral epidemics using epidemiological and evolutionary models

Mathematical modelling is useful for understanding infectious disease epidemics, and for estimating

Design and Performance Evaluation of a Battery-Assisted Fuel-Less Generator Using a Permanent Magnet Synchronous Generator with Automated Feedback Control

The energy insufficiency experienced in Nigeria is estimated to affect upwards of 85 million people,