Logo Lanfrica
  • Home
  • Atlas
  • Insights
  • Docs
  • Sign in

© 2026 Lanfrica. All rights reserved. All copyrights of the resources shown on the Lanfrica website belong to the original copyright holders, unless explicitly stated otherwise.

Performance investigation of solar ejector cooling system: Case study area-Addis Ababa, Ethiopia

Domain:

environment and energyclimate

Record type:

paper
Creator:
MihBal
Publisher:
Zenodo
Host:avatar
This study investigates the performance of a solar ejector cooling system under both on-design and off-design operating conditions, focusing on the case study area of Addis Ababa, Ethiopia. Data crucial to the analysis were gathered from the Ethiopian National Meteorology Agency (ENMA) over six consecutive years (2013-2018). The system's performance was evaluated through hourly and monthly analyses under on-design conditions, yielding promising results. Under on-design conditions, the system demonstrated favorable performance metrics. Specifically, at noontime in March, when the design points were set at Tg = 90°C, Tc = 30°C, and Te= 12°C, the system achieved a total hourly maximum coefficient of performance (COP) of 0.2049 and a cooling capacity of 186.9 W/m². Furthermore, the study determined that a collector area of 22.3 m² per ton of cooling capacity is required during noontime for all cooling seasons in Addis Ababa, Ethiopia. Additionally, an off-design operating condition map was developed for the system. The findings indicate that the solar ejector cooling system can effectively provide cooling during office hours (8:00-15:00) in Addis Ababa, Ethiopia

Visit

doi.orgzenodo.org

Languages

Amharic

Tags

Performance analysisEjectorSolar cooling systemOn and off-designOperating condition map

Licenses

Creative Commons Attribution 4.0 Internationalhttps://creativecommons.org/licenses/by/4.0/legalcode

Similar

Reliability Assessment of the Transport System, Addis Ababa Case StudyFACTORS AFFECTING GREEN AREA PROJECT PERFORMANCE: THE CASE OF KOLFE KERANYO SUB CITY, ADDIS ABABAPERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIAStudy on Pantograph Arcing and Investigation of its Influencing Parameters: Case Study-Addis Ababa Light Rail TransitPerformance Analysis of Spectrum Scenarios for Outdoor LTE Small Cell Planning: The Case of Addis Ababa, EthiopiaEFFECT OF ENTREPRENEURIAL ORIENTATION ON BUSINESS PERFORMANCE: THE CASE OF MEDIUM SCALE ENTERPRISES IN ADDIS ABABA, ETHIOPIA.

Reliability Assessment of the Transport System, Addis Ababa Case Study

Abstract The subject of the article is the method of assessing the reliability of t

FACTORS AFFECTING GREEN AREA PROJECT PERFORMANCE: THE CASE OF KOLFE KERANYO SUB CITY, ADDIS ABABA

This study was explored the factors affecting the performance of green area projects in Kolfe Kerany

PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA

In order to understand the behavior and to determine the effective operational parameters of a solar

Study on Pantograph Arcing and Investigation of its Influencing Parameters: Case Study-Addis Ababa Light Rail Transit

In electrified railways sliding contact between pantograph and overhead contact wire is one of the m

Performance Analysis of Spectrum Scenarios for Outdoor LTE Small Cell Planning: The Case of Addis Ababa, Ethiopia

Due to the increasing penetration of smart devices and data intensive applications, mobile network o

EFFECT OF ENTREPRENEURIAL ORIENTATION ON BUSINESS PERFORMANCE: THE CASE OF MEDIUM SCALE ENTERPRISES IN ADDIS ABABA, ETHIOPIA.

IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF BUSINESS ADMINTRATION.