Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings

Domaine:

healthcare
Créateur:
GiaMicAndEli
Éditeur:
Ovi
Hôte:
The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermined criteria and to demonstrate the suitability of the device for low resource settings. A device, which fulfilled stipulated criteria in being inexpensive, semiautomated, and solar powered, was validated according to the International Protocol of the European Society of Hypertension; it was then subjected to field testing in 716 subjects from 2 centers in Uganda and 1 in Zambia. The Omron HEM-SOLAR having previously fulfilled accuracy criteria of the International Protocol for both systolic blood pressure (SBP) and diastolic blood pressure (DBP), fulfilled criteria for SBP, but not for DBP, when revalidated. In field testing, average SBPs and DBPs were 120.5±21.6/74.6±13.8 mm Hg and 122.3±21.8/71.2±14.0 mm Hg, respectively, with the auscultatory technique and the Omron HEM-SOLAR, respectively. Between-device agreement in defining SBP was 93.7%. The Omron HEM-SOLAR was favored over the mercury sphygmomanometer by both patients and investigators. In summary, considering the accuracy, robustness, relatively low cost, operational simplicity, and advantages such as solar power, the Omron HEM-SOLAR is likely to be a valuable device for improving BP measurement in low-resource settings with nonphysician health workers.

Visit

doi.org

Similaires

A Novel Low-cost Bubble CPAP device with Pressure Monitoring and Controlling System for Low Resource SettingsReusable Core Needle Biopsy Device for Low-Resource Settingssj-docx-1-dhj-10.1177_20552076221109060 - Supplemental material for A novel low-cost bubble continuous positive airway pressure device with pressure monitoring and controlling system for low resource settingsMeasuring blood pressure with a wearableDevelopment of a novel device for objective respiratory rate measurement in low-resource settingsCircular Medical Device Design for Low Resource Settings in sub-Saharan Africa

A Novel Low-cost Bubble CPAP device with Pressure Monitoring and Controlling System for Low Resource Settings

Purpose: Africa contributed to one-third of the world’s neonatal mortality burden. In the sub-Sahara

Reusable Core Needle Biopsy Device for Low-Resource Settings

Purpose The core needle biopsy (CNB) procedure is an essential part of breast cancer diagnosis. Cu

sj-docx-1-dhj-10.1177_20552076221109060 - Supplemental material for A novel low-cost bubble continuous positive airway pressure device with pressure monitoring and controlling system for low resource settings

Supplemental material, sj-docx-1-dhj-10.1177_20552076221109060 for A novel low-cost bubble continuou

Measuring blood pressure with a wearable

Measuring blood pressure with a wearable

Poster presented at the Deep Learning Indaba 2023 by Dylan Geldenhuys

Development of a novel device for objective respiratory rate measurement in low-resource settings

Objective To evaluate a novel device (Respimometer) for objective measurement of

Circular Medical Device Design for Low Resource Settings in sub-Saharan Africa