Objective To evaluate a novel device (Respimometer) for objective measurement of respiratory rate (RR) in low-resource settings. Design Description of prototype development, with proof-of-concept pilot field study at four paediatric healthcare facilities in Butembo, Democratic Republic of the Congo (DRC). The instrument was tested in healthy adult volunteers (n=10) and Congolese children (n=42) and compared with timed breaths (adults) or by reference comparator capnography (children). Correlation and Bland-Altman plots were generated for paired measurements. Results The Respimometer is shaped like an oral thermometer and is placed in the mouth of the participants. RR is measured by thermistors positioned at the nasal outlet, which detect the temperature change between inhaled and exhaled breaths. In adult volunteers, the correlation coefficient between the delivered RR and the Respimometer measurement was median 0.992 (IQR 0.980–0.999). Measurement bias was −0.50 min −1 (95% CI −1.1 to +0.07, p=0.093), with upper and lower limits of agreement of −5.2 min −1 and 4.2 min −1 , respectively. Among Congolese children, there was no evidence of bias: mean difference in RR +1.0 min −1 (95% CI −2.1 to +4.1, p=0.52). The upper and lower limits of agreement were −18 and +20 min −1 , respectively. Conclusion The Respimometer can accurately measure the RR in healthy adults and children in DRC. A simple and accurate instrument could facilitate the diagnosis of pneumonia by community health workers in low-income and middle-income countries, leading to reduced pneumonia-related deaths.

Visit

doi.org

Similaires

A Novel Low-cost Bubble CPAP device with Pressure Monitoring and Controlling System for Low Resource SettingsReusable Core Needle Biopsy Device for Low-Resource SettingsA New Solar-Powered Blood Pressure Measuring Device for Low-Resource SettingsCircular Medical Device Design for Low Resource Settings in sub-Saharan AfricaEvaluation of a continuous neonatal temperature monitor for low-resource settings: a device feasibility pilot studysj-docx-1-dhj-10.1177_20552076221109060 - Supplemental material for A novel low-cost bubble continuous positive airway pressure device with pressure monitoring and controlling system for low resource settings

A Novel Low-cost Bubble CPAP device with Pressure Monitoring and Controlling System for Low Resource Settings

Purpose: Africa contributed to one-third of the world’s neonatal mortality burden. In the sub-Sahara

Reusable Core Needle Biopsy Device for Low-Resource Settings

Purpose The core needle biopsy (CNB) procedure is an essential part of breast cancer diagnosis. Cu

A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings

The management of high blood pressure (BP) is particularly inadequate in low-income countries, where

Circular Medical Device Design for Low Resource Settings in sub-Saharan Africa

Evaluation of a continuous neonatal temperature monitor for low-resource settings: a device feasibility pilot study

Objective Evaluate a novel continuous temperature monitor in a low-resource neonatal ward. Desig

sj-docx-1-dhj-10.1177_20552076221109060 - Supplemental material for A novel low-cost bubble continuous positive airway pressure device with pressure monitoring and controlling system for low resource settings

Supplemental material, sj-docx-1-dhj-10.1177_20552076221109060 for A novel low-cost bubble continuou