Logo Lanfrica
  • Accueil
  • Atlas
  • Analyses
  • Documentation
  • Sign in

© 2026 Lanfrica. Tous droits réservés. Tous les droits d'auteur des ressources affichées sur le site Web Lanfrica appartiennent aux détenteurs de droits d'auteur d'origine, sauf indication contraire explicite.

Re-testing as a method of implementing external quality assessment program for COVID-19 real time PCR testing in Uganda

Domaine:

healthcare

Type de record:

paper
Créateur:
EriFreJocJoh
Éditeur:
Pub
Hôte:
Background Significant milestones have been made in the development of COVID19 diagnostics Technologies. Government of the republic of Uganda and the line Ministry of Health mandated Uganda Virus Research Institute to ensure quality of COVID19 diagnostics. Re-testing was one of the methods initiated by the UVRI to implement External Quality assessment of COVID19 molecular diagnostics. Method participating laboratories were required by UVRI to submit their already tested and archived nasopharyngeal samples and corresponding meta data. These were then re-tested at UVRI using the WHO Berlin protocol, the UVRI results were compared to those of the primary testing laboratories in order to ascertain performance agreement for the qualitative & quantitative results obtained. Ms Excel window 12 and GraphPad prism ver 15 was used in the analysis. Bar graphs, pie charts and line graphs were used to compare performance agreement between the reference Laboratory and primary testing Laboratories. Results Eleven (11) Ministry of Health/Uganda Virus Research Institute COVID19 accredited laboratories participated in the re-testing of quality control samples. 5/11 (45%) of the primary testing laboratories had 100% performance agreement with that of the National Reference Laboratory for the final test result. Even where there was concordance in the final test outcome (negative or positive) between UVRI and primary testing laboratories, there were still differences in CT values. The differences in the Cycle Threshold (CT) values were insignificant except for Tenna & Pharma Laboratory and the UVRI(p = 0.0296). The difference in the CT values were not skewed to either the National reference Laboratory(UVRI) or the primary testing laboratory but varied from one laboratory to another. In the remaining 6/11 (55%) laboratories where there were discrepancies in the aggregate test results, only samples initially tested and reported as positive by the primary laboratories were tested and found to be false positives by the UVRI COVID19 National Reference Laboratory. Conclusion False positives were detected from public, private not for profit and private testing laboratories in almost equal proportion. There is need for standardization of molecular testing platforms in Uganda. There is also urgent need to improve on the Laboratory quality management systems of the molecular testing laboratories in order to minimize such discrepancies.

Visit

doi.org

Licenses

http://creativecommons.org/licenses/by/4.0/

Similaires

Implementation of Antibody Rapid Diagnostic Testing versus Real-Time Reverse Transcription-PCR Sample Pooling in the Screening of COVID-19: a Case of Different Testing Strategies in AfricaImplementation of COVID-19 Laboratory Testing Certification Program (CoLTeP) in African RegionReplication Data for: Epidemiology of COVID-19 infections on routine PCR and serology testing in Coastal KenyaEpidemiology of COVID-19 infections on routine polymerase chain reaction (PCR) and serology testing in Coastal KenyaExternal quality assessment of bacterial identification and antimicrobial susceptibility testing in African national public health laboratories, 2011–2016The Use Of Dried Tube Specimens Of Plasmodium Falciparum In An External Quality Assessment Program To Evaluate Health Worker Performance For Malaria Rapid Diagnostic Testing In Healthcare Centers In Togo

Implementation of Antibody Rapid Diagnostic Testing versus Real-Time Reverse Transcription-PCR Sample Pooling in the Screening of COVID-19: a Case of Different Testing Strategies in Africa

Coronavirus disease 2019 (COVID-19) has wreaked havoc across the globe; although the number of cases

Implementation of COVID-19 Laboratory Testing Certification Program (CoLTeP) in African Region

Objectives: Coronavirus disease 2019 was declared a global pandemic in March 2020 with correct and

Replication Data for: Epidemiology of COVID-19 infections on routine PCR and serology testing in Coastal Kenya

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection began in Wuhan, Chin

Epidemiology of COVID-19 infections on routine polymerase chain reaction (PCR) and serology testing in Coastal Kenya

Background: There are limited studies in Africa describing the epidemiology, cl

External quality assessment of bacterial identification and antimicrobial susceptibility testing in African national public health laboratories, 2011–2016

Abstract Background In 2002, the World Hea

The Use Of Dried Tube Specimens Of Plasmodium Falciparum In An External Quality Assessment Program To Evaluate Health Worker Performance For Malaria Rapid Diagnostic Testing In Healthcare Centers In Togo

Abstract Background: The use of rapid diagnostic tests (RDTs) to diagnose malaria is com